callback

Clean air on the construction site – with the AEROXX 750!

Get your promotional set now: consisting of the AEROXX 750 construction air cleaner with a total of 2x H13 main filters + 6x pre-filters.  


Protect your health

Dust-free working in rooms thanks to constant extraction and filtration

Clean tools

No damage caused by dust contamination

You leave behind a clean construction site

Your customer is completely satisfied


Bye bye dust, hello clean air!


Our air purifier effectively filters dust from the air it draws in and returns it to the environment in a purified state. This not only protects health, but also actively contributes to preventing and reducing damage caused by dust in accordance with TRGS 504.

2-STAGE FILTER SYSTEM

The cost-effective pre-filter traps coarse dirt such as visible dust and larger particles. This protects the high-quality HEPA main filter from damage and significantly extends its service life. As a result, the air cleaning performance remains consistently high. The result: less maintenance, lower operating costs, and reliable air quality on the construction site.

2-STAGE FILTER SYSTEM


The cost-effective pre-filter traps coarse dirt such as visible dust and larger particles. This protects the high-quality HEPA main filter from damage and significantly extends its service life. As a result, the air cleaning performance remains consistently high. The result: less maintenance, lower operating costs, and reliable air quality on the construction site.

Comfort without compromise

Effortless filter checking: The access door is easy to open, allowing you to insert and remove the filters in no time at all—without any tools.

Comfort without compromise

Effortless filter checking: The access door is easy to open, allowing you to insert and remove the filters in no time at all—without any tools.

Secure your offer now!

The all-inclusive package: Everything you need for the first few weeks – just unpack, get started, and work dust-free.

Aeroxx 750 building air purifier

Bye bye dust, hello clean air!


Our building air purifier effectively filters dust from the air that is sucked in and returns it to the environment in a purified state. This not only protects your health, but also actively contributes to the prevention and reduction of damage caused by dust in accordance with TRGS 504. Laborious cleaning work caused by settling dust is reduced. The resulting time savings are an added bonus for tradesmen and builders alike. The building air purifier is also ideal for challenging building materials such as inhalable and respirable dusts, e.g. concrete, plaster and hardwood dusts, ensuring a safe working environment.

Flexible in use: Use it for air circulation alone or in combination with supply/exhaust air hoses - for maximum efficiency on any construction site.
Optional:
(Ø 250 mm, 6 m length, 5.3 kg)
(Ø 150 mm, 6 m length, 3.2 kg)
Documents are loaded...

Safety notes

Documents are loaded...
Standard scope of delivery:
  • 1x main filter (HEPA H13) item no. 466101,
  • 1x pre-filter,
  • 1x power cord

Additional scope of delivery:
  • 1x main filter H13 (item no. 466101)
  • 1x pre-filter 5 pcs. (item no. 466118)
(Valid only during the promotional period)
Equipment: 
  • Pre-filter (5 Pack) for coarse dirt (filter area 0,35m²) item no. 466118
  • Main filter (HEPA H13) for fine dust (filter area 2,83m²) item no. 466101

Technical data: 
  • Voltage:  220-240V / 50-60Hz
  • Power consumption (max.):  170 watts ECO - 250 watts MAX
  • Nominal power:  3200 watts Power output via power outlet
  • Volume flow:  580 m³/h ECO - 750 m³/h MAX
  • Negative pressure:  1.9 mbar ECO - 2.5 mbar MAX
  • Sound pressure level:  66,1 dB(A) at MAX
  • Dimensions:  38 x 38 x 41 cm
  • Weight: 10.5 kg
  • Power cord length: 3 m

VARIABLE APPLICATION OPTIONS

The Aeroxx can be used for recirculation air purification or in negative pressure mode.

Directly in the room.

One or more devices can be set up, even in series connection.

Intake at the dust protection wall/door.

The air purifier is placed with the intake in an opening in the dust protection wall. It draws the dusty air out of the room, filters it, and releases it back into the adjacent room.

Air ducting with optional hoses.

The exhaust air hose is fed through an opening in the dust protection wall into the adjacent room, while the supply air hose can be placed close to the dust source. The device sucks in the dusty air, filters it, and releases the cleaned air into the adjacent room, for example.

Supply air hose in the room. Device and purified exhaust air in the adjacent room.

The air purifier is placed with the intake hose in an opening in the dust protection wall. It draws in the dusty air close to the dust source, filters it, and releases it into the adjacent room, for example.

Device in the room. Exhaust air hose leads into the adjacent room.

The air purifier is placed in the room and the exhaust air hose is fed through an opening in the dust protection wall into the adjacent room. The device sucks in the dusty air, filters it, and releases the purified air into the adjacent room, for example.

Device in the room. Exhaust hose out to the window.

The air purifier is placed in the room. The exhaust hose is placed outside via a window. The device sucks in the dusty air, filters it, and discharges the purified air outside.

Matching

NEW
Supply air hose for Aeroxx 750
⌀ 25 cm ​, flexibel bis zu 6 Meter​ lang
EUR193.85*
NEW
Exhaust air hose for Aeroxx 750
⌀ 15 cm, flexible up to 6 meters long
EUR128.76*
NEW
Main filter H13 Aeroxx 750
Hauptfilter für Feinstaub, Filterfläche 2,83 m²
EUR128.76*
NEW
Aeroxx 750 pre-filter
Vorfilter für Grobschmutz, Filterfläche 0,35 m²
EUR128.76*
Universal vacuum cleaner - iPulse M-1635 Safe
Safety vacuum cleaner with Permanent-Clean filter cleaning, dust class M and basic equipment
EUR1,010.31*
Universal vacuum cleaner - iPulse M-1635 Safe Plus
Safety vacuum cleaner of dust class M, with professional equipment
EUR1,069.81*
Universal vacuum cleaner - iPulse H-1635 Safe Plus
Dust class H safety vacuum cleaner with professional equipment
EUR1,188.81*

FAQ - in a nutshell

Our air purifier distinguishes between the supply air hose and the exhaust air hose. The larger supply air hose is placed close to the dust source and can extract the dust in a more targeted manner. The smaller exhaust air hose prevents unwanted dust swirling when blowing out the filtered air in the dusty work area. It is therefore advisable to use a dust protection wall for extraction.
The hoses enable air to be conveyed over the specified distance. A certain loss of performance due to the hoses is unavoidable.

The construction air purifier has a two-stage filter system with a pre-filter and main filter. The pre-filter protects the main filter from coarse dirt and reduces wear and tear. The pre-filter is more of a disposable product, so it should be changed frequently, even daily in very dusty environments.
The main filter is HEPA 13 certified. Its service life depends on how often the pre-filter is changed and how much dust the construction air purifier is exposed to. Even occasional cleaning of the main filter cannot prevent the fine pores of the filter material from becoming clogged. As a rule of thumb, the main filter should also be replaced after approximately 10 pre-filters have been used.
An indication that the filters need to be cleaned or replaced is when the red warning light on the control panel of the construction air cleaner lights up. This indicates that the air flow is severely impaired.

The Aeroxx 750 was developed for small to medium-sized rooms. The larger the rooms, the lower the air exchange rate (circulation of the entire room air). To ensure that the air is sufficiently filtered, the air exchange rate should not fall below 10 to 15. This corresponds to rooms of approximately 14-20 m². However, the unit is also effective in larger rooms, but the recommended air exchange rate can be increased at any time by adding a second or third unit.
Formula: Volume flow (750 m³/h) divided by room air in m³ (room length x room width x ceiling height) = air exchange (number / h)
Calculation example: 750 m³/h : 50 m³ (4 m length x 5 m width x 2.5 m height) = 15-fold air exchange

The power output of the socket on the first device allows up to 10 devices to be connected in series. This ensures perfect air exchange even in larger/open rooms.

Construction air purifiers filter dust-laden indoor air during construction work. Since construction dust is hazardous to health, the fine dust that enters the air during grinding or sawing work despite extraction by certified construction dust extractors must also be combated. A construction air purifier is therefore always a safe addition to a construction dust extractor.
Of course, it is also the first choice for freehand or demolition work when a construction dust extractor cannot be used.

When using construction air cleaners, it is advisable to close doors and windows or install dust protection walls in order to achieve a higher air exchange rate. For recirculation mode, the construction air cleaner is placed in the work area and draws air through the filter, but also releases it back into the same room after filtering. Negative pressure operation achieves the best results, but only works if the room is sealed as airtight as possible (dust protection walls, taping over air vents, etc.).
Negative pressure in the work area is created by extracting the air and simultaneously releasing it into the adjacent room via the hose or by integrating the construction air cleaner into the dust protection wall.